Oxygen Concentrator
Model:7F-3 / 7F-5B
User's Manual
DO NOT OPERATE THIS UNIT WITHOUT FIRST
READING AND UNDERSTANDING THIS MANUAL
Table ofContents
Advertisement
Do you have a question about the 7F-3 and is the answer not in the manual?
Questions and answers
Related Manuals for Yuwell 7F-3
-
Medical Equipment Yuwell 7F-5B User Manual
Oxygen concentrator (21 pages)
-
Medical Equipment Yuwell 7E-B5 Operation Instructions
Portable phlegm suction unit (2 pages)
-
Medical Equipment Yuwell 7E-B5 User Manual
Portable phlegm suction unit (9 pages)
-
Medical Equipment Yuwell 7B-1 User Manual
Manual suction apparatus (2 pages)
-
Medical Equipment Yuwell 7F-5A User Manual
(13 pages)
-
Medical Equipment Yuwell 7E-A User Manual
Portable phlegm suction unit (6 pages)
-
Medical Equipment Yuwell 7A-23B User Manual
Electric suction apparatus (10 pages)
-
Medical Equipment Yuwell BreathCare PAP User Manual
Positive airway pressure units (32 pages)
-
Medical Equipment Yuwell YX102 User Manual
Finger pulse oximeter (8 pages)
-
Medical Equipment Yuwell 8F-5A User Manual
Oxygen concentrator (21 pages)
-
Medical Equipment Yuwell 8F-3A User Manual
(14 pages)
-
Medical Equipment Yuwell YH-550 User Manual
Breathcare pap positive airway pressure units (20 pages)
-
Medical Equipment Yuwell BreathCare PAP User Manual
Positive airway pressure units (18 pages)
-
Medical Equipment Yuwell BreathCare PAP User Manual
Positive airway pressure units (58 pages)
-
Medical Equipment Yuwell 8F-10 User Manual
(21 pages)
-
Medical Equipment Yuwell YX3 Series Quick Start Manual
Fingertip pulse oximeter (8 pages)
Summary of Contents for Yuwell 7F-3
- Page 1 Oxygen Concentrator Model:7F-3 / 7F-5B User’s Manual DO NOT OPERATE THIS UNIT WITHOUT FIRST READING AND UNDERSTANDING THIS MANUAL...
-
Page 2: Table Of Contents
TABLE OF CONTENTS SAFETY NOTES………………………………………………………………….2-6 FEATURES………………………………………………………………………..7-9 HANDLING………………………………….……………………………………10 OPERATING & INSTALLATION……......………………………11-16 MAINTENANCE…………………………………………………………………17-18 TROUBLESHOOTING……………………..……………………………………19-20 OTHER ATTENTION ITEMS……………………………………………………21-22 EMC INFORMATION……………………… ……………………………..…..23-25 - 1 -... -
Page 3: Safety Notes
SAFETY NOTES WARNING: INDICATION FOR USE: This device designed to extract oxygen from atmospheric air. It will typically be an electrically-powered molecular sieve (artificial zeolite) used to separate nitrogen from room air. The oxygen concentration is variable, depending on the flow rate being utilized. - Page 4 SAFETY NOTES Be certain to place the device so all sides are at least 10 cm (4 inches) away from walls, draperies, furniture, or other obstruction. MUST place the oxygen concentrator in a well-ventilated area. Always place the device in the expected position that the operator can hear the audio alarming.
- Page 5 SAFETY NOTES Ⅵ. RADIO FREQUENCY INTERFERENCE This equipment generates, uses and can radiate radio frequency energy and, if not installed according with the instructions, may cause harmful interference to other devices in the vicinity. However, there is no guarantee that interference will not occur in a particular installation.
- Page 6 There is a risk of fire associated with oxygen enrichment during oxygen therapy. Do not use the oxygen concentrator or accessories near sparks or open flames. To ensure receiving the therapeutic amount of oxygen delivery according to your medical condition, 7F-3/7F-5B Oxygen Concentrator by YUWELL must...
- Page 7 SAFETY NOTES Do not lubricate fittings, connections, tubing, or other accessories of the oxygen concentrator to avoid the risk of fire and burns. Use only spare parts recommended by the manufacturer to ensure proper function and to avoid the risk of fire and burns. Use of this device at an altitude above 2000m or outside temperature of 5℃~40℃...
-
Page 8: Features
Ⅲ. SPECIFICATIONS 1. Power Supply: ~230V, 50Hz 2. Input Power: 【7F-3】320VA; 【7F-5B】400VA 3. Maximum Recommend Flow Rate: 【7F-3】3L/min; 【7F-5B】5L/min 4. Oxygen Concentration at Nominal Output Pressure of 0kPa (Measured after warm up 30minutes): 【7F-3】3L/min: 93±3%; 【7F-5B】5L/min0: 95.5%~87% 5. Maximum limited pressure: 50kPa ( with humidifier bottle ) 6. - Page 9 FEATURES 8. Oxygen Concentration vs. Oxygen Flow: Tested at standard temperature and pressure dry conditions. (101.3kPa, 20℃, dry) 【7F-3】 Oxygen Concentration ( % ) Flow ( L/min ) 93±3% 93±3% 93±3% 93±3% 80%~86% 70%~80% 【7F-5B】 Oxygen Concentration ( % ) Flow ( L/min ) 95.5%~87%...
- Page 10 FEATURES 15. Safety System: Over Current or Connection Loosen (Loss Power): Alarming and Shut Down Compressor Over Hot: Unit Shut Down Pressure Failure: Alarming and Shut Down Compressor Failure: Alarming and Shut Down Low Oxygen Concentration 16.
-
Page 11: Handling
HANDLING Ⅰ. UNPACKING Unless use the oxygen concentrator, retain containers and packing materials for storage until use of the concentrator is required. 1. Check for any obvious damage to the carton or its contents. If damage is evident, please notify the carrier or local dealer. 2. -
Page 12: Operating & Installation
OPERATING & INSTALLATION Ⅰ. FEATURE VIEW Figure 1: view of the machine view of the display panel Figure 2: Humidifier Components - 11 -... - Page 13 Open the transparent door, unscrew the bottle from the humidifier counter-clockwise. Fill the bottle with pure water (or distilled water) to the level indicated by the manufacturer. 2. Screw securely the bottle back counterclockwise. (Recommend to use Yuwell Humidifier p/n: 20005727 and its preferred location is shown as Figure 1.)
- Page 14 OPERATING & INSTALLATION NOTE: To properly read the flowrate, locate the prescribed flowrate line on the flowmeter. Next, turn the flow knob until the ball rises to the line. Now, center the ball on the L/min line prescribed. If the flowrate on the flowmeter ever falls below 0.5L/min, check tubing or accessories for blocked or kinked tubing or a defective humidifier bottle.
- Page 15 OPERATING & INSTALLATION Ⅳ. ALARM SIGNAL Concentrator has following failure Alarm function: 1) Pressure failure 2) Compressor failure 3) Low oxygen concentration 4) Over temperature 5) Low flowrate 6) Power loss Note: All the alarms are LOW PRIORITY. Alarm can only be ceased by turning off the device. ...
- Page 16 OPERATING & INSTALLATION 3. Pressure failure alarm - yellow light illuminates, alarm sounds, and panel shows word “E1” or “E2”. Total unit shutdown. Switch immediately to backup oxygen supply. Call supplier immediately. 4. Compressor failure alarm - yellow light illuminates, alarm sounds, and panel shows word“E3”...
- Page 17 OPERATING & INSTALLATION Ⅶ. SYMBOLS Symbol Symbol Description Description Caution Alternating current Type BF Applied part Class Ⅱ Equipment OFF (power disconnection ON (power connection to the mains) from the mains) No open flame: Fire, open ignition No smoking source and smoking prohibited Fragile Keep Up...
-
Page 18: Maintenance
MAINTENANCE NOTE: Power should be disconnected before beginning preventive maintenance on the concentrator. The concentrator is specifically designed to minimize routine preventive maintenance at intervals of once per year. In places with high dust or soot levels, maintenance may need to be performed more often. The following must be performed at a minimum of one year in service to assure years of additional reliability. - Page 19 MAINTENANCE DO NOT operate the concentrator without installing filter, or while filter is wet. These actions could permanently damage the concentrator. 3. Clean Humidifier 1) Remove the humidifier bottle from the humidifier cap then clean the bottle. 2) Remove the humidifier tube and diffuser then clean them. The humidifier must clean or replace once a week at least or as necessary.
-
Page 20: Troubleshooting
2) Adjust the flow rate only under yellow light the advice of a physician. 【7F-3】3L/min; illuminate, alarm 【7F-5B】5L/min 3) If the phenomenon is still appeared, the device can be used but please contact the supplier. Concentrator 1) System cycle pressure is too 1) Clean or replace the filter. - Page 21 TROUBLESHOOTING Symptom Probable cause Solution 1) Stop using the device, please contact 1) Compressor circuit is opened. immediately the supplier Concentrator working, the yellow light 2) fan failure ; or concentrator air inlet 2) inside temperature is too high ; illuminate , alarm, the and air outlet blocked ;...
-
Page 22: Other Attention Items
OTHER ATTENTION ITEMS Ⅰ. GAS PASS OPERATION SKETCH MAP Filter Compressor Heat Exchanger Valve Oxygen/Nitrogen Molecular Assembly Sieve Separation Muffler Oxygen Nitrogen Commute Valve Bacilli Pressure Flowmeter Product Filter Regulator Tank Check Valve Oxygen Humidifier Outlet Ⅱ. ELECTRICAL RATIONALE Transformer Display Board Oxygen Main Board... - Page 23 OTHER ATTENTION ITEMS Ⅲ. PACKING LIST 1. Oxygen Concentrator: 1 unit User & Technical Manual: 1 piece Fuse tube:T5AH250V~/φ5×20,2pcs 4. Firesafe Cannula Valve [ Bpr firesafe ] piece :1 connect tube :φ5×φ9×40mm silicone tube 6. Nasal Oxygen Cannula 2m piece :1 Ⅳ.DEVICE DISPOSAL Contact the local cit or town offices for proper disposal instructions for oxygen...
-
Page 24: Emc Information
EMC Information Use of this equipment adjacent to or stacked with other equipment should be avoided because it could result in improper operation. If such use is necessary, this equipment and the other equipment should be observed to verify that they are operating normally. - Page 25 EMC Information emission Guidance and declaration of manufacturer -Electromagnetic Immunity test test level 8 kV contact Electrostatic discharge (ESD) ± ±15 kV Air IEC 61000-4-2 Electrical fast transient /bursts ±2 kV for power supply lines IEC 61000-4-4 Surge ±1 kV line to line IEC 61000-4-5 0.5 cycle at 0% U...
- Page 26 EMC Information Test specifications for ENCLOSURE PORT IMMUNITY to RF wireless communications equipment Test Maximum IMMUNITY Band Distance frequency Service Modulation power TEST LEVEL (MHz) (MHz) (V/m) Pulse modulation 380 - 390 TETRA 400 18 Hz GMRS 460, 430 - 470 ±5 kHz deviation FRS 460 1 kHz sine...
- Page 27 Address: Yunyang Industrial Park, Danyang, Jiangsu, P.R.China TEL: 86-511-86900833 Shanghai International Holding Corp. GmbH (Europe) Address: Eiffestrasse 80, 20537 Hamburg Germany TEL: 0049-40-2513175 Notified Body: Name: TÜV SÜD Product Service GmbH Address: Ridlerstr. 65, 80339 MÜnchen, Germany Document No.: YY-7F-3/5B-01(B/1) 2019.06 - 26 -...
This manual is also suitable for:
7f-5b